Sftwdown; Sftwdown-Fail - Cisco ONS 15327 User Documentation

Hide thumbs Also See for ONS 15327:
Table of Contents

Advertisement

Alarm Procedures
Invisible laser radiation may be emitted from the aperture ports of the single-mode, fiber-optic
Warning
modules when no cable is connected. Avoid exposure and do not stare into open apertures.
Caution
Always use the supplied ESD wristband when working with a powered ONS 15327. Plug the wristband
cable into the ESD jack located on the lower-right outside edge of the shelf assembly.
Procedure: Clear the SF-P Condition on an OC-N Card
Verify that the user-provisionable BER threshold is set at the expected level:
Step 1
a.
Click the Provisioning > Line tabs.
b.
c.
d.
e.
f.
Using an optical test set, measure the power level of the line and ensure it is within the guidelines.
Step 2
Step 3
Verify that optical receive levels are within the acceptable range.
Verify that single-mode fiber is being used.
Step 4
Verify that a single-mode laser is being used at the far-end node.
Step 5
If the problem persists, the transmitter at the other end of the optical line may be failing and need
Step 6
replacement.

14.4.108 SFTWDOWN

A software download in progress (SFTWDOWN) alarm occurs when the XTC is downloading or
transferring software. No action is necessary. Wait for the transfer or the software download to complete.
It can take up to 30 minutes for software to be updated on a standby XTC card. Wait the full time period
Caution
before removing the card. Premature removal can cause flash corruption.

14.4.109 SFTWDOWN-FAIL

Cisco ONS 15327 User Documentation, R3.3
14-76
From the CTC node view, double-click the card reporting the alarm to bring up the card view.
Under the SF BER column on the Provisioning pane, check that the cell entry is consistent with what
the system was originally provisioned for. The default setting is 1E-4.
If the entry is consistent with what the system was originally provisioned for, continue to step 2.
If the entry is not consistent with what the system was originally provisioned for, click the cell to
reveal the range of choices and click the entry that is consistent with what the system was originally
provisioned for.
Click Apply.
Minor, Non-Service-Affecting
Minor, Non-Service-Affecting
Chapter 14
Alarm Troubleshooting
June 2002