Chapter 10
Alarm Monitoring and Management
10.3.3 Alarm Profile Editing
Table 10-6
profile column.
Table 10-6 Alarm Profile Editing Options
Button
Store
Rename
Clone
Reset
Remove
10.3.4 Alarm Severity Option
You change or assign alarm severity using a menu. To view this menu, right-click the alarm you want to
change in its alarm profile column. Seven severity levels appear for the alarm:
•
•
•
•
•
•
•
Transparent and Unset only appear in alarm profiles; they do not appear when you view alarms, history,
Note
or conditions.
10.3.5 Row Display Options
The Alarm Profiles subtab also displays two check boxes at the bottom of the screen: Hide default
values and Hide identical rows. The Hide default values check box highlights alarms with nondefault
severities by clearing alarm cells with default severities. The Hide identical rows check box hides rows
of alarms that contain the same severity for each profile.
June 2002
lists and describes the five profile editing options available when you right-click in an alarm
Description
Saves a profile in either a node or a file
Changes a profile name
Creates a new profile that contains the same alarm severity
settings as the highlighted profile (the profile being cloned)
Restores a profile to the state of that profile before it was last
applied or to the state when it was first loaded, if it has not yet
been applied
Removes a profile from the table editor
CR: Critical
MJ: Major
MN: Minor
NR: Not reported
NA: Not alarmed
TR: Transparent
UNSET: Unset/Unknown (not normally used)
Cisco ONS 15327 User Documentation, R3.3
Alarm Profiles