Chapter 14
Alarm Troubleshooting
Click Apply.
Step 4

14.4.83 MANRESET

A manual system reset (MANRESET) condition means a user performed a manual system reset by
right-clicking a card and chose Reset. Resets performed during a software upgrade also prompt the
alarm. This condition clears automatically, when the card finishes resetting.

14.4.84 MAN-REQ

The manual switch request on a facility/equipment (MAN-REQ) alarm occurs when a user initiates a
manual switch request on an OC-N card or UPSR path. Clearing the manual switch clears the
MANUAL-REQ alarm.
Procedure: Clear the Manual Switch and the MAN-REQ Condition on an OC-N Card
From network view, click the Circuits tab.
Step 1
Highlight the circuit.
Step 2
Click Edit and click the UPSR tab.
Step 3
From the Switch State menu, highlight Clear.
Step 4
Click Apply and click Close.
Step 5

14.4.85 MEA (AIP)

If the mismatch between entity/equipment type and provisioned attributes (MEA) alarm is reported
against the AIP, the fuse in the AIP board may have blown, and the AIP needs replacement.
Procedure: Clear the MEA Alarm on the AIP
The fuse in the AIP board may be blown and the board needs to be replaced. Login to
Step 1
http://www.cisco.com/TAC for information on obtaining a return materials authorization (RMA) for the
AIP or call the Cisco Technical Assistance Center (1-800-553-2447).
June 2002
Not Alarmed (NA) (Condition)
Not Alarmed (NA) (Condition)
Critical, Service-Affecting
Cisco ONS 15327 User Documentation, R3.3
Alarm Procedures
14-61