Procedure: Verify Successful Turn-Up of MICs

Install MIC A in Slot 8.
Step 1
The slots are keyed to ensure that cards are installed in the correct slot.
Verify that the power and ground cables are installed correctly.
Step 2
With power applied to MIC A, insert the fan-tray assembly and verify that the fans activate.
Step 3
The fans will only activate if at least one XTC card is installed.
If you require redundant power, more than 14 DS-1s, or you are using DS-3s, install MIC B in Slot 7. If
Step 4
MIC B is not required, proceed to
With power applied to MIC B, unplug MIC A from the backplane (do not remove it completely) and
Step 5
verify that the fans are still running.
Disconnect power before removing MICs from the ONS 15327.
Warning
Plug MIC A back into the backplane and reconnect power.
Step 6
Verify that the card appears in the correct slot on the CTC node view (default login) screen.
Step 7
Verify that the card is white on the CTC node view screen.
Step 8
If MIC A was unplugged in
Step 9
slot and is white on the CTC node view screen.
Refer to
June 2002
Slot 4
4
Slot 3
3
Slot 2
2
Slot 1
1
Step
Step
5, plug it back into the backplane and verify that it appears in the correct
Chapter 2, "Software Installation,"
Slot 5
Slot 6
Slot 7
Slot 8
7.
for more information about using CTC.
Cisco ONS 15327 User Documentation, R3.3
Card Installation and Turn-Up
5
Fan
Tray
6
Slot
7
8
1-19