Rep4. Xerographics; Rep4.1 Ros Assy (Pl4.1.1) - Fuji Xerox DocuPrint CM305 df Service Manual

Hide thumbs Also See for DocuPrint CM305 df:
Table of Contents

Advertisement

REP4. XEROGRAPHICS

REP4.1 ROS ASSY (PL4.1.1)

[Removal]
1)
Remove the CASSETTE ASSY 250 MG AIO. (REP2.1)
2)
Open the COVER ASSY FRONT (PL1.2.1).
NOTE
3)
Remove the PHD ASSY. (REP4.6)
NOTE
4)
Remove the FUSING UNIT. (REP6.1)
5)
Remove the COVER ASSY SIDE R AIO. (REP1.8)
6)
Remove the COVER ASSY SIDE L AIO. (REP1.9)
7)
Remove the COVER POLE OUT AIO. (REP1.1)
8)
Remove the SHIELD ASSY ESS AIO. (REP8.5)
9)
Remove the COVER POLE IN AIO. (REP1.3)
10) Remove the COVER SCANNER LOW AIO. (REP1.2)
11) Remove the COVER REAR AIO. (REP1.5)
12) Remove the COVER TOP AIO. (REP1.4)
13) Remove the CHASSIS ASSY LVPS. (REP8.12)
14) Remove the HARNESS ASSY FRONT USB (PL10.1.13) and BRACKET ASSY USB
(PL10.1.14). (REP9.6)
15) Remove the TRAY ASSY. (REP9.3)
16) Remove the ADF ASSY. (REP9.1)
17) Remove the IIT ASSY SUB. (REP9.5)
18) Remove the PLATE ASSY TOP. (REP8.7)
19) Disengage the two connectors (P/J40
and 41) on the PWBA MCU
(PL8.3.6), release the harness from
the EDGE SADDLE (PL8.3.2).
Cover the drum of the PHD ASSY to avoid exposure to light.
The FUSING UNIT part is very hot. Take added care not to get burned when
performing the service operation.
Chapter 4 Disassembly / Assembly and Adjustments
4 - 126

Advertisement

Table of Contents
loading