Fuji Xerox DocuPrint CM305 df Service Manual page 705

Hide thumbs Also See for DocuPrint CM305 df:
Table of Contents

Advertisement

Chain
Description
-Link
Fax Commu. Speed Setting for
825-701
display on panel
Threshold 0 for detection of
825-702
External Tel Hook Status
Threshold 1 for detection of
825-703
External Tel Hook Status
Threshold 2 for detection of
825-704
External Tel Hook Status
Supp. process of detecting the
825-705
status of ETSI Standard Ext. Tel
Hook
Supp. process for detecting the
825-706
status of ETSI Stan. Ext. Tel
Hook
950-001
950-002
950-003
950-004
950-005
Name
UI_FAX_SPEED
EXTEL_HOOK_THRESH_0
EXTEL_HOOK_THRESH_1
EXTEL_HOOK_THRESH_2
CAPAB_EXTEL_HOOK_SUPPLEM
ENT
EXTEL_HOOK_SUPPLEMNT_VOL
THRESH
FORGET_ERROR_secret
CODE_CHECK_secret
PMQAT_BOARD_secret
DONT_DEL_TXFILE
DONT_PR_RCVFILE
Value Label
Default
0:2400,
1:4800,
2:9600,
4
3:14400,
4:33600
6
0 ~ 255V
10
0 ~ 255V
20
0 ~ 255V
0: Disable
0
1: Enable
10,15,20(V)
15
0
0
6 – 59
Chapter 6 General
Details
Access
Change the 3 pieces of system
data simultaneously.
2400:
CAPAB_V34=Not capable
G3M_TX_MODEM_SPEED=1
G3M_RX_MODEM_SPEED=1
4800:
CAPAB_V34=Not capable
G3M_TX_MODEM_SPEED=2
USER
G3M_RX_MODEM_SPEED=2
9600:
CAPAB_V34=Not capable
G3M_TX_MODEM_SPEED=3
G3M_RX_MODEM_SPEED=4
14400:
CAPAB_V34=Not capable
G3M_TX_MODEM_SPEED=5
G3
When
ONHOOK_LVS_THRESH_HI
is " 0 ", this setting is used as
External Tel Hook Status
Detection Threshold.
If a faulty detection of an Ext.
Tel Hook status occurs despite a
change of
CE
ONHOOK_LVS_THRESH_HI,
change either
EXTEL_HOOK_THRESH_0 or
2 for action. At this time, decide
a voltage change to be used as a
threshold, using an actual value
measured on a defective line.
When
ONHOOK_LVS_THRESH_HI
is "1", this setting is used as Ext.
Tel Hook Status Detection
Threshold.
If a faulty detection of an Ext.
Tel Hook status occurs despite a
change of
CE
ONHOOK_LVS_THRESH_HI,
change either
EXTEL_HOOK_THRESH_0 or
2 for action. At this time, decide
a voltage change to be used as a
threshold, using an actual value
measured on a defective line.
When
ONHOOK_LVS_THRESH_HI
is "2", this setting is used as Ext.
Tel Hook Status Detection
Threshold.
If a faulty detection of an Ext.
Tel Hook status occurs despite a
change of
CE
ONHOOK_LVS_THRESH_HI,
change either
EXTEL_HOOK_THRESH_0 or
2 for action. At this time, decide
a voltage change to be used as a
threshold, using an actual value
measured on a defective line.
Enable/disable starting the supp.
CE
process for Ext. Tel.
Supp. Process for Ext. Tel:
Voltage Value by which to
CE
decide Ext. Tel is off hook
CE
CE
CE
CE
CE