Step
Checking the connectors of the Exit Sensor in the FUSING
UNIT for connection.
Check the connections between the PWBA MCU and
FUSING UNIT.
Are P/J17 and P/J171 connected correctly?
11
Checking the HARNESS ASSY FUSING UNIT MG AIO for
continuity.
Remove the FUSING UNIT.
12
Disconnect J17 from the PWBA MCU.
Is each cable of J17 <=> P171 continuous?
NOTE: P171 is attached to the frame.
Checking the power to the Exit Sensor in the FUSING UNIT.
Disconnect the connector of J17 on the PWBA MCU.
13
Is the voltage across J17-1pin <=> ground on the PWBA
MCU, about +3.3 VDC?
Checking the Exit Sensor for operation.
Check the voltage across J17-3pin <=> ground on the
14
PWBA MCU.
Does the voltage change, when the actuator of the Exit
Sensor is operated?
Check
2 - 140
Chapter 2 Troubleshooting
Remedy
Yes
Reconnect the
connector(s) P/
Go to step 12.
J17 and/or P/J171
correctly.
Replace the
HARNESS ASSY
Go to step 13.
FUSING UNIT MG
AIO.
Replace the KIT
PWBA MCU.
Go to step 14.
(Refer to
REP8.10.)
Warning: Start the
operation after the
FUSING UNIT has
cooled down.
Replace the KIT
Replace the
PWBA MCU.
FUSING UNIT.
(Refer to
(Refer to REP6.1.)
REP8.10.)
After replacement,
be sure to clear
the life counter
value.