RAID Xanadu User Manual page 176

Table of Contents

Advertisement

(2) Changing Network Settings by Changing Management Server Network Settings
To perform disk array unit initialization by Individual Setting in Storage Manager after faults have
occurred in network setup during initialization, it can also be executed after temporarily making
network settings of the current disk array unit coincide with management server network settings
and changing them to make monitoring from Storage Manager possible.
Confirmation of IP
address that was set
Connection
configuration check
Host IP address
modification
Start of disk array
unit monitoring
Disk array unit
network setup
Host IP address
restoration
Disk array connection
confirmation
Since disk array unit initialization is not complete, host connection port setup, license unlocking,
logical disk binding, and other initialization must be performed separately.
Refer to 11.2 "Setup Modification" to make settings.
*1: If an IP address is not provided, refer to SVP Number (controller number), IP Address,
Subnetmask, and Gateway, which are output in message number "iSM14483" in the message
display area of the Storage Manager client (Web GUI). Once you have restarted (reconnected)
the Storage Manager client (Web GUI), since messages are output only from that time, refer to
SVP Number (controller number), IP Address, Subnetmask, and Gateway, which are output in
message number "iSM14483" in the log file of the Storage Manager server. For the Storage
Manager server log file output destination, refer to "Log Output" in the "User's Manual" of the
OS being used.
Provide the IP address, subnet mask, and gateway address
noted in the network setting screen of the initialization wizard.
(*1)
Check the settings of the IP address, subnet mask, and gateway
address in each controller of the disk array and of the IP
address, subnet mask, and gateway address of the network
interface card (hereafter, NIC) in the host on which the Storage
Manager server is installed (hereafter, management server), as
well as the physical connection configuration. (*2) (*3)
Temporarily change the IP address, subnet mask, and gateway
address of the management server NIC so that the IP address of
the management server NIC is in the same subnet as the IP
address of each controller. (*4) (*5)
Referring to the installation guide, perform environment setup
so that disk array monitoring is performed through a LAN
connection from the Storage Manager server and restart the
Storage Manager server.
Referring to the "Configuration Setting Tool User's Manual
(GUI)", set the IP address, subnet mask, and gateway address
of the disk array. (*6) (*7) (*8)
After restoring the temporary IP address, subnet mask, and
gateway address of the management server NIC, restart the
Storage Manager server.
Confirm that disk array monitoring is being performed by the
Storage Manager client.
-
-