NGL200/NGM200
Example:
[SOURce:]VOLTage:RAMP:DURation <duration>
[SOURce:]VOLTage:RAMP:DURation?
Sets or queries the duration of the voltage ramp.
Parameters:
<duration>
Example:

7.7.3 Digital I/O

The DIO subsystem contains the commands for configuring a Digital I/O function for
the output channels.
DIO:FAULt:CHANnel
DIO:FAULt:SOURce
DIO:FAULt[:STATe]
DIO:OUTPut:SOURce
DIO:OUTPut[:STATe]
DIO:FAULt:CHANnel <arg0>
Sets or queries channel selection for the digital output fault source.
See "operation modes" in
Parameters:
<arg0>
User Manual 1178.8736.02 ─ 05
*RST:
0
INST OUT1
VOLT:RAMP ON
VOLT:RAMP? -> 1
EasyRamp function of Ch1 is activated
numeric | MIN | MAX | DEFault
numeric
Duration of the ramp function in seconds.
MIN
Minimum duration of the ramp function at 0.00 s.
MAX
Minimum duration of the ramp function at 10 s.
DEF
Default duration of the ramp function at 0.01 s.
Range:
0.01 to 10.00
*RST:
0.01
Default unit: s
VOLT:RAMP:DUR 4
VOLT:RAMP:DUR? -> 4
Duration of the ramp function is set at 4 s.
...................................................................................................... 137
.......................................................................................................138
.........................................................................................................138
.................................................................................................... 138
...................................................................................................... 139
Figure
6-18.
1 | 2
Remote Control Commands
Advanced Operating Commands
137

Hide quick links:

Advertisement

Table of Contents
loading