WAGO I/O-SYSTEM 750 Manual page 66

Bluetooth rf-transceiver
Table of Contents

Advertisement

66
Process Image
Example: Configuring Bluetooth
The user can only change parameter 0 of the 750-644 I/O module. This includes
configuration of the process image and Mailbox size.
Request (Application)
Parameters
TGL_MS
PRM_RW
MORE_PRM
A0 ... A7
PRM0 ... PRM7
PRM8 ... PRM14 MBX_LEN
PRM15
Response (I/O Module)
Parameters
TGL_MS
A0 ... A7
TIMEOUT
BUF_OFL
PRM_ERR
Pos : 71 /D okumentation allgemei n/Glieder ungs elemente/---Seitenwechs el--- @ 3\mod_1221108045078_0.doc x @ 21810 @ @ 1
®
Process Data and Mailbox
Value
Description
!= TGL_SM
Enter instruction
= TRUE
Write access
= FALSE
Parameter data transmission is completed.
0
Parameter address
DATA_LEN
12, 24 or 48 byte data length
6, 12 or 18 byte Mailbox size
MBX_MODE
1 (not adjustable)
Value
Description
= = TGL_SM
Instruction completed
0
Address parameter data mirrored
FALSE, TRUE
Monitoring time expired
FALSE, TRUE
Access outside the 750-644 I/O module
parameter range
FALSE, TRUE
Parameter / parameter set error
Version 2.0.0, valid from FW/HW Version 03/03
WAGO-I/O-SYSTEM 750
®
750-644 Bluetooth
RF-Transceiver
Manual