200
Appendix
Offset
Register
(byte)
No.
60
15 ... 18 16
76
19
80
92
22 ... 23 1
100
24 ... 11
4
13*7
Register
464
115 ... 1
28
*)
750-644 I/O module or Bluetooth
Pos : 105 /Dokumentati on allgemei n/Gli ederungsel emente/---Seitenwec hs el--- @ 3\mod_1221108045078_0.doc x @ 21810 @ @ 1
Length
Data Type Definition
(bytes)
Password
1
Inquiry time
1
Reserved
2
Reconnection time
12
Reserved
MaxTXPower
1
DefaultTXPower
Reserved
6
364
Slave configuration for 13
devices
*)
, 28 bytes per device
13*28
Byte 1 ... 6: MAC ID
Reg.
Byte 7: Bind/Unbind
Byte 8: Max. process data length
Byte 9: PI size of the remote
*)
device
Byte 10: RFCOMM_CHANNEL
Byte 11: Reserved
Byte 12: Supported profiles
Byte 13 ... 28: UserFriendlyName
Reserved
48
®
SPP device
WAGO-I/O-SYSTEM 750
750-644 Bluetooth
Description
See appendix "Reading the Local Bluetooth
Password" and "Writing the Local Bluetooth
Password".
Maximum duration of a query. The exact time results
from: Inquiry time x 1.28 sec.
Time between two connection attempts, LSB first (see
appendix "Reading Back Time Setting – Between Two
Attempts to Establish a Connection" and "Setting the
Time Setting – Between Two Attempts to Establish a
Connection").
Restriction of the maximum transmission power, value
in dBm, value range [0 ... 20]
Transmission power used for paging and inquiry, value
in dBm, value range [0 ... 20]
Configuration for 13 remote devices
*)
:
Local address of the 750-644 I/O module, LSB first
(see appendix "Reading the MAC ID of a Remote
Device")
*)
1 – Device
was connected
0 – other (see appendix "Granting Access Permission
to a Device" and "Deleting Access Permission for a
Device")
Configured width of the slots in the PI (size of the
available process data)
PI of the remote device
the Size of a Slot for Data Transfer in the Master PI")
RFCOMM channel to which the connection is
established
Received value for the bit field of the supported
profiles. The individual values are linked binarily using
OR:
1 – Real-time
2 – SPP
User-friendly name (see appendix "Reading the User-
Friendly Name of an Allowed Device").
Version 2.0.0, valid from FW/HW Version 03/03
®
RF-Transceiver
®
®
*)
:
*)
(see appendix "Determining
Manual

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

750-644