64
Process Image
Calculate the Maximum Parameter Data of the Bus Module (System
Parameters)
Request (Application)
Parameters
TGL_MS
PRM_RW
A0 ... A7
Response (I/O Module)
Parameters
TGL_MS
A0 ... A7
PRM0 ... PRM15
Set Factory Settings (System Parameters)
Request (Application)
Parameters
TGL_MS
PRM_RW
A0 ... A7
Response (I/O Module)
Parameters
TGL_MS
A0 ... A7
By writing 255 to the parameter address, the factory setting of the I/O module
subsystem for the 750-644 I/O module is restored. This includes the process
image and Mailbox size. The settings of the Bluetooth
accessed through the mailbox interface and can be separately reset to standard
values via mailbox command.
Value
Description
!= TGL_SM Enter instruction
= FALSE
Read access
255
Address parameter data length
Value
Description
= = TGL_SM Enter instruction
255
Read access
N
Number of parameter data in the address range
0 ... (n-1), n ∈ {N < 250}
Value
Description
!= TGL_SM Enter instruction
= FALSE
Write access
255
Factory setting
Value
Description
= = TGL_SM Instruction completed
255
Set address factory setting, mirrored
Version 2.0.0, valid from FW/HW Version 03/03
WAGO-I/O-SYSTEM 750
®
750-644 Bluetooth
RF-Transceiver
®
subsystem can only be