Reading Back The Time Setting - Between Two Attempts To Establish A Connection - WAGO I/O-SYSTEM 750 Manual

Bluetooth rf-transceiver
Table of Contents

Advertisement

WAGO-I/O-SYSTEM 750
®
750-644 Bluetooth
RF-Transceiver
Arguments
Parameters
MBX_TARGET_TABLE
_AND_INDEX
MBX_QOS_SETTINGS
Response
Byte
0
1
Return values
Parameters
MBX_RESULT
12.3.6.11 Reading Back the Time Setting – Between Two Attempts to Establish
a Connection
GetReconnectionTimePeriod, 0x8A
This command is used to read back the time interval between two attempts to
reestablish the connection to a 750-644 I/O module.
Conditions
Mailbox size
6
Request
Byte
0
1
Response
Byte
0
1
2
3
Manual
Version 2.0.0, valid from FW/HW Version 03/03
Value
Bit 0 ... 3
Bit 4 ... 7
MBX_BQM_NONE (0x01)
MBX_BQM_BEST_EFFORT
(0x02)
MBX_BQM_GUARANTEED
(0x03)
7
6
2
2
T
Value
MBX_CMD_OUT_OF_RANGE An index greater than 6 was used.
MBX_CMD_INVALID_ARG
12
18
Config. Real-time Ad-hoc Master Slave
7
6
2
2
MBX_GETRECONNECTIONTIMEPERIOD
T
7
6
2
2
MBX_GETRECONNECTIONTIMEPERIOD
T
MBX_RECONNECTTIME (LSB)
MBX_RECONNECTTIME (MSB)
Description
Table index
Index 0 ... 6 for 750-644 I/O
modules of slots 1 ... 7
Target table
"2" for WAGO_DEVICE (slots
1 ... 7)
No QoS activated (standard)
QoS is enabled in "Best Effort"
mode
QoS is enabled in the "Guaranteed"
mode
5
4
3
2
2
2
MBX_SETCONNECTIONQOS
MBX_RESULT
Description
No valid target table was used or an invalid
value for MBX_QOS_SETTINGS was
selected.
Mode
Device role
-
-
5
4
3
2
2
2
-
5
4
3
2
2
2
MBX_RESULT
Appendix
2
1
2
2
Save
config.
-
2
1
2
2
2
1
2
2
179
0
2
Reboot
-
0
2
0
2

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

750-644