HCIT jam service check

Action
Step 1
Open the media tray and check the media path.
Is it free of obstructions?
Step 2
Check the following:
Push down on the lift plate and check if the spring works.
Open and close the tray, then check if the HCIT closes properly.
Is the tray functioning properly?
Step 3
Check the interface cable of the printer or upper level option for damage.
Check the separator roller tires and gears:
Make sure that the rollers are free from contamination
Manually turn the gears and check if it causes the rollers to turn.
Does the error remain?
Step 4
Check the sensor (trailing edge):
Make sure that the sensor is properly installed and seated.
Check if the sensor is in good condition. If damaged, then replace the
sensor. Go to
"Sensor (HCIT pick) removal" on page
Reseat the connector (J8) on the controller PCBA, then POR the machine.
Does the error remain?
Step 5
Check the pick roller assembly for proper installation. Fully press the pick
roller assembly toward the sensor to make sure the mounting latches are
properly engaging the slot in the shaft.
Does the problem remain?
Step 6
Check the pick roller assembly to make sure that the rollers are free from
contamination and paper dust.
Is the pick roller assembly free of wear or damage?
Step 7
Check the pick roller assembly for proper installation. Fully press the pick
roller assembly toward the sensor to make sure the mounting latches are
properly engaging the slot in the shaft.
Does the problem remain?
Yes
Go to step 2.
Go to step 3.
Go to step 4.
Go to step 5.
556.
Go to step 6.
Go to step 7.
Go to step 8.
Diagnostic information
178
7463
No
Remove all
obstructions along the
paper path.
Replace the HCIT. Go to
"HCIT and drawer
assembly removal" on
page
537.
Replace the separator
roller. Go to
"HCIT
separator roll
assembly removal" on
page
538.
The problem is solved.
The problem is solved.
Replace the pick roller
assembly. Go to
"Drawer pick roller
removal " on
page
522.
The problem is solved.

Hide quick links: