Feed To All Bins; Sensor Test; Diverter Test - Lexmark MX81 Series Service Manual

Hide thumbs Also See for MX81 Series:
Table of Contents

Advertisement

3
Select one of the following:
Single—Feeds a single page
Continuous—Continuously feeds pages until X is pressed

Feed To All Bins

This test verifies that media can be fed to the standard bin or any installed output options. No information is printed
on the media.
To run the Feed To All Bins test:
1
From the Diagnostics menu, navigate to: OUTPUT BIN TESTS > Feed to All Bins.
The printer feeds a separate piece of media to the standard bin first, then it feeds a separate piece of media to each
output bin installed in order.
The test continuously prints the Print test pages until X is pressed.
2
Press Back to return to the OUTPUT BIN TESTS menu.

Sensor Test

This test verifies that the output bin sensors are working correctly.
To run this test:
1
From the Diagnostics menu, navigate to:
Output Bin Tests > Sensor Test > Standard Bin
Testing... appears while the printer is verifying the state of the sensor.
The control panel displays the current state of the sensor.
2
Manually actuate the sensor to make it toggle between empty and full. If the sensor does not toggle, then the
sensor is malfunctioning.
3
Press X to exit the test.

Diverter Test

This test verifies that the mailbox option's output media diverters are working correctly. If more than one mailbox
option is installed, then this test exercises the diverters on all installed mailbox devices.
To run the Diverter Test:
1
From the Diagnostics menu, navigate to:
OUTPUT BIN TESTS > Diverter Test.
Diverter Test Testing... appears while the printer is verifying the state of the diverter.
2
Press X to exit the test.
Service menus