GSM 07.07
Parameter
<currency> String type; three-character currency code (e.g. "GBP", "DEM"); character set as specified
by command select TE character set +CSCS
<ppu>
String type; price per unit; dot is used as a decimal Separator (e.g. "2.66")
<passwd>
String type; SIM PIN2

12.12. AT+CCWE Call Meter Maximum Event

AT+CCWE Call Meter Maximum Event
Test Command
AT+CCWE=?
Read Command
AT+CCWE?
Write Command
AT+CCWE=[<mode>]
Reference
GSM 07.07
Parameter
<mode>
0
1
NOTE
Unsolicited result codes supported:
+CCWV Shortly before the ACM (Accumulated Call Meter) maximum value is reached, an unsolicited
result code +CCWV will be sent, if enabled by this command. The warning is issued approximately when
5 seconds call time remains. It is also issued when starting a call if less than 5s call time remains
M35_AT_Commands_Manual
Response
+CCWE: (list of supported <mode>s)
OK
Response
+CCWE: <mode>
OK
Response
OK
If error is related to ME functionality:
+CME ERROR: <err>
Disable call meter warning event
Enable call meter warning event
Confidential / Released
GSM/GPRS Module
M35 AT Commands Manual
166 / 186