Display Units For Temperature And Transport Speed - Kodak X-Omat 460 RA Operator's Manual

Hide thumbs Also See for X-Omat 460 RA:
Table of Contents

Advertisement

Display Units for Temperature and Transport Speed

Description
Procedure
20
You may select either english or metric ''Display Units'' for the temperature and
transport speed readings on the display panel. If you select english units, the
displayed temperature will be in degrees Fahrenheit, and the displayed transport speed
will be in inches per minute. If you select metric units, the displayed temperature will
be in degrees Celsius, and the displayed transport speed will be in centimeters per
minute.
[1]
To change ''Display Units'' for temperature and transport speed, press the
''GO TO SETUP'' key.
READY
135 F = DRYER SETPOINT
_______________________________________
|
/\
\/
|
DRYER
DRYER
|
[2]
Enter the 4 digit access code.
|
|
1
2
|
[3]
Press the ''OPTIONS'' key.
|
CYCLE
SETUP
|
PROC-
|
ESS
[4]
Press the ''DISPLAY UNITS'' key.
|
REPLEN
TEMP
|
MODE
LOCK
|
[5]
Press either—
''SELECT ENGLISH'' for °F and in./min or
(a)
''SELECT METRIC'' for °C and cm/min.
(b)
|
SELECT
SELECT
|
ENGLISH
METRIC
|
[6]
Immediately, press the ''DONE/RETURN'' key to store the entry.
STD
|
|
|
SELECT
DISPLAY
GO TO
|
|
|
CYCLE
FIX
SETUP
|
|
|
TEMP
|
|
|
CANCEL
|
|
|
3
4
REQUEST
|
|
|
|
|
|
DONE/
|
|
|
OPTIONS
LANG
RETURN
|
|
|
|
|
|
DISPLAY
DONE/
|
|
|
UNITS
MORE
RETURN
|
|
|
|
|
|
DONE/
|
|
|
RETURN
|
|
|
636736