Password Protection Function (From FW 1.04)
Password protection function is available on all VDI100 models.
Parameter 13-06 represents a first level of access control to parameters without any password protection.
•
•
Parameter 13-07 allows to lock the access to all parameters except main frequency. This parameter is
available both from Keypad and PC Tool configurator.
1. Parameter Lock Key Code STATUS
Parameter 13-07 can have the following STATUS:
13-07 = 00000
13-07 = 00001
13-07 = 00002
2. Parameter Lock Key Code SETTINGS
2.1 The procedure to set a new password is the following (the new password for the example is 12345):
1st entry
DSP/
FUN
The Parameter Lock Key Code STATUS become: 00001. User continue to have free access to parameters
depending on 13-06 parameter setting. To lock parameters, password must be confirmed (see step 2.2). When
a new password is set, please use all precautions to recover it simply.
2.2 After step 2.1, the procedure to Lock the access to all parameters consists into confirming the password:
DSP/
FUN
2nd entry
DSP/
FUN
The Parameter Lock Key Code STATUS become: 00002. User has no access to parameters setting.
2.3 After step 2.2, the procedure to UNLock the access to all parameters is the following:
DSP/
FUN
Lifting
Password
DSP/
FUN
3. Lost password recovery
If a password set by customer is lost, please contact Gefran Service Team for assistance.
.
242
No password is set (Default is 00000 which means no Password)
Password is set and waiting for confirmation but Lock function is disabled
Password is confirmed and Lock function is enabled
READ/
ENTER
or
Set Password failed
▼
▲
or
READ/
ENTER
▼
▲
or
Password failed to lift
▼
▲
or
READ/
ENTER
▼
▲
or
Password successfully lifted
▲
▼
READ/
ENTER
READ/
ENTER
READ/
ENTER
READ/
ENTER
READ/
ENTER
VDI100 • Instruction manual