Input Current and Fuse Specifications
11.5.
230V class
Model
1007
1015
2022
2037
2055
3075
4110
4150
4185
5220
400V class
Model
1007
1015
1022
2037
2055
3075
3110
3150 / 4150
4185
4220
5300
5370
5450
5550
6750
6900
71100
71320
71600
Fuse type:
Voltage Range:
344
Horse power
kVA
1
1.9
2
3
3
4.2
5
6.7
7.5
9.5
10
12.6
15
17.9
20
22.9
25
28.6
30
32.4
100% of rated output current
Horse
kVA
power
1
2.6
2
3.2
3
4.2
5
7
7.5
11.3
10
13.7
15
18.3
20
23.6
25
29.7
30
34.3
40
45.7
50
57.2
60
69.3
75
85.4
100
114
125
137
150
165
175
198
215
225
America: choose semiconductor fuse to comply with UL.
Europe: aR type.
For 230V class inverter, use 300V class fuse.
For 400V class inverter, use 600V class fuse.
Single phase
100% of rated
Rated input
output current
current
HD/ND
HD/ND
(A)
(A)
5/6
9.4/11.3
8/9.6
14.7/17.9
11/12
20.3/22.1
17.5/22
-
25/30
-
33/42
-
47/56
-
60/69
-
73/80
-
85/110
-
Rated input current
HD/ND
(A)
3.4/4.1
4.2/5.4
5.5/6.9
9.2/12.1
14.8/17.5
18/23
24/31
31/38
39/44
45/58
60/73
75/88
91/103
118/145
150/168
180/208
216/250
260/296
295/328
3 phases
Rated input
Three-phase
current
fuse rating
HD/ND
(A)
5.4/6.5
8.5/10.3
11.7/12.8
18.7/22.3
26.3/31.6
34.5/41.7
51.1/60.9
65.2/75
79.4/85.9
92.4/119.6
3 phases
Three-phase
fuse rating
HD/ND
(A)
(A)
3.7/4.5
10
5.3/5.9
16
6.0/7.5
16
9.6/11.6
25
15.5/18.2
40
18.7/24.0
50
25.0/32.3
63
33.7/41.3
80
42.4/47.8
100
48.9/58.7
120
65.2/78.3
150
81.5/95.7
200
98.9/112
250
130/159
300
159/181
400
181/229
500
229/275
600
275/325
700
325/361
700
VDI100 • Instruction manual
(A)
20
30
50
50
63
100
120
150
200
250