gefran VDI100 Series Instruction Manual page 174

General purpose full vector inverter
Hide thumbs Also See for VDI100 Series:
Table of Contents

Advertisement

Function
Setting
Name
0
Auxiliary frequency
Frequency Reference
1
Gain (FGAIN)
Frequency Reference
2
bias (FBIAS)
Output Voltage Bias
3
(VBIAS)
Coefficient of accele-
4
ration and deceleration
reduction (K)
5
DC braking current
Over-torque detection
6
level
Stall prevention Level
7
During Running
8
Frequency lower limit
9
Jump frequency 4
10
Added to AI1
11
Positive torque limit
12
Negative torque limit
Regenerative Torque
13
Limit
Positive / negative
14
torque limit
Torque command/
15
Torque limit for speed
control
Torque command/
16
Torque compensation
PTC Overheat Pro-
17
tection
04-05=0: Auxiliary frequency
When parameter 00-05 = 1 (main frequency from external control) the auxiliary speed reference frequency can
be activated via the multi-speed input commands (see table 4.4.7). The auxiliary frequency command can be
set via AI2. The maximum output frequency is set by 01-02, Fmax =100%.
04-05=1: Frequency Reference Gain (FGAIN)
Multi-function analog input AI2 can be used to adjust the frequency reference gain of analog input AI1.
The total frequency reference gain of terminal AI1 is the internal gain set by parameter 04-02 times FGAIN.
The maximum frequency reference for AI1 is 100%.
174
Table 4.4.11 Multi-function analog input list (04-05 setting)
Screen display
AUX.Freq Ref
Max Output Frequency (01-02, Fmax) = 100%
Aggregated gain =
Freq Ref Gain
AI1 = 04-02 * FGAIN
Aggregated bias =
Freq Ref Bias
AI1 = 04-03 * FBIAS
Aggregate output voltage =V/f curve voltage +
Output Volt Bias
VBIAS
Actual acceleration and deceleration time = accele-
Tacc/Tdec Scaling
ration and deceleration time
Adjust the DC braking current (0 ~ 100%) based
DC Inj Current
on analog input. When the inverter rated current =
100%, DC braking current 07-07 is disabled.
Change over-torque detection level based on
Over Tq Level
over-torque detection level, at this time, 08-15 is
disabled.
Adjust the action level (30% ~ 200%) of stall
Run Stall Level
prevention in operation based on analog input. The
inverter rated current =100%.
Adjust the lower limit (0 to 100%) of frequency com-
mand based on analog input, the maximum output
Ref. Low Bound
= 100%. The lower limit of frequency command is
the greater one of the actual frequency command's
lower limit 00-13 or the multi-function analog input.
Jump frequency 4.
Jump Freq 4
100% = maximum output frequency
Added to AI1.
Add to AI1
100% = maximum output frequency
Positive Tq Limit
100% = motor's rated torque
Negative Tq Limit
100% = motor's rated torque
Regen. Tq Limit
100% = motor's rated torque
+/- Tq Limit
100% = motor's rated torque
Tref/Tq Limit
100% = motor's rated torque
Tq Compensation
100% = motor's rated torque
Use the sensor near the fan in the motor to stop
PTC overheat Stall
from overheats.
Contents
Control mode
V/f
PM
V/f
+
SLV
SV
SV
PG
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
X
X
O
O
O
O
O
O
O
O
O
X
O
O
O
O
O
O
O
O
X
X
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
X
X
O
O
O
X
X
O
O
O
X
X
O
O
O
X
X
O
O
O
X
X
X
O
O
X
X
X
O
O
O
O
O
O
O
VDI100 • Instruction manual
PM
SLV2
SLV
O
O
O
O
O
O
O
O
O
O
X
O
O
O
X
O
O
O
O
O
O
O
O
X
O
X
O
X
O
X
X
X
X
X
O
O