gefran VDI100 Series Instruction Manual page 145

General purpose full vector inverter
Hide thumbs Also See for VDI100 Series:
Table of Contents

Advertisement

Value
Name
Switching between motor 1/
40
motor 2
41
PID Sleep
42
PG disabled
43
PG integral reset
Mode switching between
44
speed and torque
45
Negative torque command
46
Zero-servo command
47
Fire Mode
48
KEB acceleration
49
Parameters writing allowable
Unattended Start Protection
50
(USP)
Mode switching between
51
speed and position
Multi Position Reference
52
Enable
2-Wire Self Holding Mode
53
(Stop Command)
54
Reserved
55
Reserved
56
Reserved
57
Reserved
58
Safety Function
59
Reserved
60
Reserved
61
Reserved
62
EPS function
63
Reserved
64
Reserved
65
Short-circuit braking
03-0X =00 2-wire control: forward operation
03-0X =01 2-wire control: reverse operation. Refer to the 2-wire operation mode in Figure 4.4.1.
03-0X =02 Multi-speed/position setting command 1.
03-0X =03 Multi-speed/position setting command 2.
03-0X =04 Multi-speed/position setting command 3.
VDI100 • Instruction manual
Function
LCD Display
Motor 2 Switch
PID Sleep
PG disabled
I-Time Reset
Speed/Torque change
Reverse Tref
Zero-Servo
Fire Mode
KEB Accel.
Write Enabled
USP
Multi Pos. Switch
Multi Pos. Enable
2-Wire (STOP)
Reserved
Reserved
Reserved
Reserved
Safety Function
Reserved
Reserved
Reserved
EPS Input
Reserved
Reserved
SC Brk
Description
ON: Start motor 2
ON: PID Sleep
ON: Speed control without PG
ON: Integral value reset of
speed control with PG
ON: Torque control mode
ON: Reverse external torque
command
ON: Zero-servo operation
ON: Turn off hardware and
software fault or alarm
protection and run the inverter
with value of 01-02 (a special
application of HVAC)
ON: KEB acceleration start
ON: all parameters are
writable
OFF: Except reference frequen-
cy (00-05) all parameters are
write-protected.
ON: After power is input, the
inverter ignores the operation
command
OFF: After power is input,
the inverter will return the
operation status before power
is cut off.
ON: Switch to position mode
OFF: Switch to speed mode
ON: Position reference is
enabled.
OFF: Position reference is
disabled.
2-Wire Self Holding Mode (
ON: Stop Command).
Reserved
Reserved
Reserved
Reserved
ON: Stop by the setting of
08-30
Reserved
Reserved
Reserved
ON:EPS input
Reserved
Reserved
ON: SC Brk turn on
Control mode
V/f
PM
V/f
SLV
SV
+PG
SV
O
O
O
O
O
O
O
O
O
O
X
O
X
X
X
X
O
X
O
O
X
X
X
O
O
X
X
X
O
O
X
X
X
O
O
O
O
O
O
O
O
O
X
X
X
O
O
O
O
O
O
O
O
O
O
X
X
X
O
O
X
X
X
O
O
O
O
O
O
O
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
O
O
O
O
O
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
X
X
X
O
O
-
-
-
-
-
-
-
-
-
-
X
X
X
X
X
PM
SLV2
SLV
O
O
O
O
X
X
X
X
X
X
X
X
X
X
O
O
X
O
O
O
O
O
X
X
X
X
O
O
-
-
-
-
-
-
-
-
O
O
-
-
-
-
-
-
X
X
-
-
-
-
O
X
145