Code
Parameter Name
15-07 T4 Current Value 2 (Mode7) 0~9999
15-08 T5 Current Value 1
15-09 T5 Current Value 2 (Mode7) 0~9999
15-10 T6 Current Value 1
15-11 T6 Current Value 2 (Mode7) 0~9999
15-12 T7 Current Value 1
15-13 T7 Current Value 2 (Mode7) 0~9999
15-14 T8 Current Value 1
15-15 T8 Current Value 2 (Mode7) 0~9999
15-16 C1 Current Value
15-17 C2 Current Value
15-18 C3 Current Value
15-19 C4 Current Value
15-20 C5 Current Value
15-21 C6 Current Value
15-22 C7 Current Value
15-23 C8 Current Value
15-24 AS1 Current Value
15-25 AS2 Current Value
15-26 AS3 Current Value
15-27 AS4 Current Value
15-28 MD1 Current Value
15-29 MD2 Current Value
15-30 MD3 Current Value
15-31 MD4 Current Value
15-32 TD Current Value
Code
Parameter Name
16-00 Main Screen Monitoring
16-01 Sub-Screen Monitoring 1
16-02 Sub-Screen Monitoring 2
16-03 Display Unit
VDI100 • Instruction manual
Group 15: PLC Monitoring Parameters
Setting Range
0~9999
0~9999
0~9999
0~9999
0~65535
0~65535
0~65535
0~65535
0~65535
0~65535
0~65535
0~65535
0~65535
0~65535
0~65535
0~65535
0~65535
0~65535
0~65535
0~65535
0~65535
Group 16: LCD Function Parameters
Setting Range
5~79
when using LCD to operate, the monitored
item displays in the first line. (default is
frequency command)
5~79
when using LCD to operate, the monitored
item displays in the second line. (default
is output frequency)
5~79
when using LCD to operate, the monitored
item displays in the third line. (default is
output current)
0~39999
Determine the display way and unit of
frequency command
0: Frequency display unit is 0.01Hz
1: Frequency display unit is 0.01%
2: Frequency display unit is rpm.
3~39: Reserved
40~9999:
Users specify the format, Input 0XXXX
represents the display of XXXX at 100%.
10001~19999:
Users specify the format; Input 1XXXX
represents the display of XXX.X at 100%.
Default
Unit
V/f
V/f
SLV
+PG
0
-
O
O
0
-
O
O
0
-
O
O
0
-
O
O
0
-
O
O
0
-
O
O
0
-
O
O
0
-
O
O
0
-
O
O
0
-
O
O
0
-
O
O
0
-
O
O
0
-
O
O
0
-
O
O
0
-
O
O
0
-
O
O
0
-
O
O
0
-
O
O
0
-
O
O
0
-
O
O
0
-
O
O
0
-
O
O
0
-
O
O
0
-
O
O
0
-
O
O
0
-
O
O
Default
Unit
V/f
V/f
SLV
+PG
16
-
O
O
17
-
O
O
18
-
O
O
0
-
O
O
Control mode
Attribute
PM
PM
SV
SLV2
SV
SLV
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
Control mode
Attribute
PM
PM
SV
SLV2
SV
SLV
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
*1
*1
*1
85