gefran VDI100 Series Instruction Manual page 80

General purpose full vector inverter
Hide thumbs Also See for VDI100 Series:
Table of Contents

Advertisement

Code
Parameter Name
12-23 Output Power Factor (Pfo)
12-24 Control Mode
12-25 AI1 Input
12-26 AI2 Input
12-27 Motor Torque
12-28 Motor Torque Current (Iq)
Motor Excitation Current
12-29
(Id)
12-30 ASR Deviation
12-31 Reserved
12-32 ASR Output
12-33 PG Feedback
12-34 Reserved
12-35 Zero-servo Pulse
12-36 PID Input
12-37 PID Output
12-38 PID Setting
12-39 PID Feedback
12-40 Reserved
12-41 Heatsink Temperature*
80
Group 12: Monitoring Parameters
Setting Range
Motor's rotation speed = output power x
(120/motor's pole number)
In PG/SV mode, motor's rotation speed is
calculated by feedback frequency.
Max limit is 65535
Display the current output power factor
Display control mode
0: VF
1: PG
2: SLV
3: SV
4: PSV
5: PMSLV
6: SLV2
Display the current Al1 input
(-10V corresponds to -100%, 10V corre-
sponds to 100%,)
Display the current Al2 input
(0V or 4mA corresponds to 0%, 10V or
20mA corresponds to 100%)
Display the current torque command
(100% corresponds to motor torque )
Display the current q-axis current
Display the current d-axis current
Display deviation of speed controller
(speed command - speed feedback)
(100% corresponds to the maximum
frequency set by 01-02 )
Display output value of speed controller
(100% corresponds to the maximum
frequency set by 01-02)
Display feedback's speed value of speed
controller
(100% corresponds to the maximum
frequency set by 01-02)
When display SV position mode, the
position error pulse number of the zero
speed servo
(the pulse number of a circle is four times
of set values of 20-27)
Display input error of the PID controller
(PID target value - PID feedback)
(100% corresponds to the maximum
frequency set by 01-02 or 01-16)
Display output of the PID controller
Display the target value of the PID
controller
(100% corresponds to the maximum
frequency set by 01-02 or 01-16)
Display the feedback value of the PID
controller
(100% corresponds to the maximum
frequency set by 01-02 or 01-16)
Display the heatsink temperature of IGBT
temperature**
Default
Unit
V/f
V/f
SLV
+PG
-
-
O
O
-
-
O
O
-
%
O
O
-
%
O
O
-
%
X
X
-
%
X
X
-
%
X
X
-
%
X
O
-
%
X
O
-
%
X
O
-
Pulse
X
X
-
%
O
O
-
%
O
O
-
%
O
O
-
%
O
O
*
°C
O
O
Control mode
PM
PM
SV
SLV2
SV
SLV
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
X
O
O
O
O
X
O
O
O
O
X
X
O
O
X
X
X
O
O
X
X
X
O
O
X
X
X
O
O
X
X
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
VDI100 • Instruction manual
Attribute

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents