gefran VDI100 Series Instruction Manual page 160

General purpose full vector inverter
Hide thumbs Also See for VDI100 Series:
Table of Contents

Advertisement

03-14
Frequency detection width
0.1~25.5 Hz
Frequency detection Level: set the multi-function output terminals R1A-R1C, R2A-R2C or PH1 (03-11, 03-12 or
03-28) to the desired detection level and bandwidth for use with multi-function output functions 2 to 5.
The time charts for the Frequency Agree Detection operation are shown in the following table 4.4.9.
Code
Parameter Name / Range
03-44
Frequency Detection Level 2
0.0~599.0 Hz
03-45
Frequency Detection Width 2
0.1~25.5 Hz
03-46
Frequency Detection Level 3
0.0~599.0 Hz
03-47
Frequency Detection Width 3
0.1~25.5 Hz
Frequency Detection: Set R1A-R1C R2A-R2C or PH1 (03-11, 03-12 or 03-28) to output frequency signal and
then set frequency confirmation and output frequency detection 1~6.
Please refer table 4.4.9.detection operation of frequency time block
Function
Detection operation of frequency confirmation
Output
Frequency
Frequency agree
Frequency
Agree
Signal
Output
Frequency
Set frequency
agree
Setting
Frequency
Agree
Signal
03-14
Output
Frequency
Output frequency
Output
detection 1
Frequency
Detection 1
Signal
OFF
160
Table 4.4.9 Frequency detection operation
Freq
Reference
03-14
FWD
REV
03-14
OFF
ON
ON
03-14
03-13
FWD
REV
03-13
03-14
OFF
ON
ON
03-13
03-13
03-14
03-13
ON
OFF
ON
Output is active when the output frequency falls within the frequen-
time
cy reference minus the frequency detection width (03-14).
Freq
Any of the digital outputs function (03-11, 03-12 or 03-28) can be
Reference
set to 3 (Frequency agree).
time
Output is active the output frequency falls within the frequency
time
detection width (03-14) of the set frequency detection level (03-13).
Any of the digital outputs function (03-11, 03-12 or 03-28) can be
set to 3 (Set frequency agree).
time
Output is active when the output frequency rises above the fre-
quency detection level (03-13) + frequency detection width (o3-14)
time
and deactivates when the output frequency falls below frequency
detection level (03-13).
03-13
Any of the digital outputs function (03-11, 03-12 or 03-28) can be
set to 4 (Output frequency detection 1).
time
Description
VDI100 • Instruction manual