gefran VDI100 Series Instruction Manual page 57

General purpose full vector inverter
Hide thumbs Also See for VDI100 Series:
Table of Contents

Advertisement

Code Parameter Name
00-00 Control Mode Selection
00-01 Motor's Rotation Direction
Main Run Command Source
00-02
Selection
Alternative Run Command
00-03
Selection
00-04 Language
Main Frequency Command
00-05
Source Selection
Alternative Frequency
00-06
Source Selection
Main and Alternative Fre-
00-07
quency Command Modes
Communication Frequency
00-08
Command Range
Communication Frequen-
00-09
cy Command Memory
Selection
Minimum frequency
00-10
detection
PID Lower Limit of Frequen-
00-11
cy Selection
00-12 Upper Frequency limit
00-13 Lower Frequency limit
00-14 Acceleration Time 1
00-15 Deceleration Time 1
00-16 Acceleration Time 2
00-17 Deceleration Time 2
00-18 *Jog Frequency
00-19 Jog Acceleration Time
00-20 Jog Deceleration Time
VDI100 • Instruction manual
Group 00: Basic Parameters
Setting Range
0: V/f
1: V/f+PG
2: SLV
3: SV
4: PMSV
5: PMSLV
6: SLV2
0: Forward
1: Reverse
0: Keypad
1: External Terminal (Control Circuit)
2: Communication Control (RS-485)
3: PLC
0: Keypad
1: External Terminal (Control Circuit)
2: Communication Control (RS-485)
3: PLC
0: English
1: Simplified Chinese
2: Traditional Chinese
3: Turkish
0: Keypad
1: External Terminal (Analog 1)
2: Terminal Command UP/DOWN
3: Communication Control (RS-485)
4: Pulse Input
5: Reserved
6: Reserved
7: AI2 Auxiliary Frequency
0: Keypad
1: External Terminal (Analog 1)
2: Terminal Command UP/DOWN
3: Communication Control (RS-485)
4: Pulse Input
5: Reserved
6: Reserved
7: AI2 Auxiliary Frequency
0: Main Frequency
1: Main frequency + Alternative Fre-
quency
0.00~599.00
0: Don't save when power supply is off.
(00-08)
1: Save when power is off. (00-08)
0:Show warning if lower than minimum
frequency
1:Run as minimum frequency if lower
than minimum frequency
0: PID Sleep Limit is Lower Limit of
Frequency
1: PID Sleep Limit is 0Hz
0.1~109.0
0.0~109.0
0.1~6000.0
0.1~6000.0
0.1~6000.0
0.1~6000.0
0.00~599.00
0.1~0600.0
0.1~0600.0
Default
Unit
V/f
V/f
SLV
+PG
0
-
O
O
0
-
O
O
1
-
O
O
2
-
O
O
0
-
O
O
1
-
O
O
3
-
O
O
0
-
O
O
0.00
Hz
O
O
0
-
O
O
0
-
O
O
0
-
O
O
100.0
%
O
O
0.0
%
O
O
*
s
O
O
*
s
O
O
*
s
O
O
*
s
O
O
6.00
Hz
O
O
-
s
O
O
-
s
O
O
Control mode
Attribute
PM
PM
SV
SLV2
SV
SLV
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
-
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
*3
*1
*1
*1
*1
*1
*1
*1
*1
57

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents