Code
Parameter Name
Operation Direction Se-
06-47
lection of Speed-Stage 15
* If the maximum output frequency of motor is over 300HZ,the frequency resolution is changed to 0.1Hz
Code
Parameter Name
Momentary Power Loss/
07-00
Fault Restart Selection
07-01 Fault Auto-Restart Time
Number of Fault Auto-Re-
07-02
start Attempts
07-03 Reserved
07-04 Direct Start at Power on
Delay of Direct Start at
07-05
Power on
DC Injection Braking Star-
07-06
ting Frequency
07-07 DC Injection Braking Current 0~100
DC Injection Braking Time
07-08
at Stop
07-09 Stop Mode Selection
07-10
~
Reserved
07-12
Low Voltage Detection
07-13
Level
07-14 Pre-excitation Time
07-15 Pre-excitation Level
DC Injection Braking Time
07-16
at Start
07-17 Reserved
07-18 Minimum Base block Time
Direction-Detection Speed
07-19
Search Operating Current
Speed Search Operating
07-20
Current
Integral Time of Speed
07-21
Searching
Delay Time of Speed
07-22
Searching
07-23 Voltage Recovery Time
Direction-Detection Speed
07-24
Search Selection
07-25 Low Voltage Detection Time 0.00~1.00
Start-up Mode Selection of
07-26
SLV Coast to Stop
Start Selection after Fault
07-27
during SLV Mode
Start after External Base
07-28
Block
70
Group 06: Automatic Program Operation Parameters
Setting Range
0: Stop
1: Forward
2: Reverse
Group 07: Start /Stop Parameters
Setting Range
0: Disable
1: Enable
0~7200
0~10
0: When the external run command is
enabled, direct start at power up
1: When the external run command is
enabled, unable to direct start at power-
up.
1.0~300.0
0.0~10.0
0.00~100.00
0: Deceleration to Stop
1: Coast to Stop
2: DC Braking Stop in All Fields
3: Coast to Stop with Timer
230V: 150~300
400V: 250~600
0.00~10.00
50~200
0.00~100.00
0.1~5.0
0~100
0~100
0.1~10.0
0.0~20.0
0.1~5.0
0: Disable
1: Enable
0: Start with speed search
1: Normal start
0: Start with speed search
1: Normal start
0: Start with speed search
1: Normal start
Default
Unit
V/f
V/f
+PG
0
-
O
O
Default
Unit
V/f
V/f
+PG
0
-
O
O
0
s
O
O
0
-
O
O
1
-
O
O
3.5
s
O
O
0.5
Hz
O
O
50
%
O
O
0.50
s
O
O
0
-
O
O
190
V
O
O
380
2.00
s
X
X
100
%
X
X
0.00
s
O
O
-
s
O
O
50
%
O
X
20
%
O
X
2.0
s
O
X
0.2
s
O
O
2.0
s
O
O
1
-
O
O
0.02
s
O
O
0
-
X
X
0
-
X
X
0
-
O
X
Control mode
PM
PM
SLV
SV
SLV2
SV
SLV
O
X
X
X
O
Control mode
PM
PM
SLV
SV
SLV2
SV
SLV
O
O
X
X
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
X
X
X
O
O
O
O
X
O
O
O
X
X
O
O
O
O
O
O
O
X
X
X
X
O
X
X
X
X
O
O
O
X
O
O
O
X
O
O
O
X
X
X
O
O
X
X
X
O
O
X
X
X
O
O
O
O
X
O
O
X
X
X
O
O
X
X
X
O
O
O
O
O
O
O
X
X
X
X
O
X
X
X
X
O
X
X
X
O
VDI100 • Instruction manual