Before to set up 00-32 Application, it should do initialized setting (parameter 13-08) first. When setting 00-32, the I/O
port function changed automatically. To avoid accident, be sure to confirm the I/O port signal of inverter and external
terminal control
00-32=2: Conveyor
00-32=3: Exhaust fan
00-32=5: Compressor
00-32=6: Hoist* Consult Gefran for the detailed settings
00-32=7: Crane* Consult Gefran for the detailed settings
VDI100 • Instruction manual
Parameter
00-00
Control mode selection
00-14
Acceleration time 1
00-15
Deceleration time 1
00-27
HD/ND selection
08-00
Stall prevention function
Parameter
00-00
Control mode selection
11-00
Direction lock selection
00-27
HD/ND selection
01-00
V/f curve selection
07-00
Momentary stop and restart selection
08-00
Stall prevention function
Parameter
00-00
Control mode selection
11-00
Direction lock selection
00-14
Acceleration time 1
00-15
Deceleration time 1
00-27
HD/ND selection
01-00
V/f curve selection
07-00
Momentary stop and restart selection
08-00
Stall prevention function
Parameter
00-00
Control mode selection
00-05
Main Frequency command source selection
11-43
Hold Frequency at start
11-44
Frequency hold Time at start
00-14
Acceleration time 1
00-15
Deceleration time 1
11-01
Carrier frequency
05-01
Frequency setting of speed-stage 0
05-02
Frequency setting of speed-stage 1
05-03
Frequency setting of speed-stage 2
03-28
Photo-coupler output
07-18
Minimum baseblock time
08-00
Stall prevention function
03-13
Frequency detection level
03-14
Frequency detection width
08-18
Selection of low-torque operation
08-19
Level of low-torque detection
08-20
Time of low-torque detection
08-09
Selection of input phase loss protection
08-10
Selection of output phase loss protection
Parameter
00-00
Control mode selection
00-05
Main Frequency Command Source Selection
00-14
Acceleration time 1
00-15
Deceleration time 1
Name
0: V/f
3.0 sec
3.0 sec
0: HD
xx0xb: Stall prevention during deceleration
Name
0: V/f
1: Forward direction only
1: ND
F
1: Enable
xx0xb: Stall prevention during deceleration
Name
0: V/f
1: Forward direction only
5.0 sec
5.0 sec
0: HD
F
1: Enable
xx0xb: Stall prevention during deceleration
Name
2: SLV
0: keypad
3.0 Hz
0.3 sec
3.0 sec
3.0 sec
5.0kHz
6.0 Hz
30.0 Hz
50.0 Hz
5 : frequency detection 2
0.3 sec
0000b: Stall prevention ineffective in decel-
eration
2.0 Hz
0.1 Hz
0: Deceleration to stop
2 %
0.5 sec
1 : Enable
1 : Enable
Name
0: V/f
0: keypad
3.0 sec
3.0 sec
Value
Value
Value
Value
Value
107