gefran VDI100 Series Instruction Manual page 63

General purpose full vector inverter
Hide thumbs Also See for VDI100 Series:
Table of Contents

Advertisement

Code Parameter Name
03-13 Frequency Detection Level
03-14 Frequency Detection Width
03-15 Current Agree Level
Delay Time of Current Agree
03-16
Detection
**Mechanical Braking Rele-
03-17
ase Level
**Mechanical Braking Level
03-18
Set
03-19 Relay (R1A-R2A) Type
03-20 Reserved
03-21 Reserved
03-22 Reserved
03-23 Reserved
03-24 Reserved
03-25 Reserved
03-26 Reserved
UP/DOWN Frequency Hold/
03-27
Adjust Selection
03-28 Photo-coupler Output
Photo-coupler Output
03-29
Selection
03-30 Selection of Pulse Input
03-31 Scale of Pulse Input
03-32 Pulse Input Gain
VDI100 • Instruction manual
Group 03: External Digital Input and Output Parameters
Setting Range
29 : During Traverse Operation Status
30 : Motor 2 Selection
31: Zero Speed Servo Status (Position Mode)
32: Communication Control Contacts
33: Reserved
34: Reserved
35: Reserved
36: Reserved
37: PID Feedback Loss Detection Output
38: Brake Release
39: Frequency Detection 1 (dedicated for
Crane)
40: Frequency Output
41: Position Agree (Position Mode)
42: Reserved
43: Reserved
44: Reserved
45: PID sleep
46: Reserved
47: Reserved
48: Reserved
49: Reserved
50: Frequency Detection 3 (> 03-44+03-45)
51: Frequency Detection 4 (< 03-44+03-45)
52: Frequency Detection 5 (> 03-46+03-47)
53: Frequency Detection 6 (< 03-46+03-47)
54: Turn on short-circuit braking
0.0~599.0
0.1~25.5
0.1~999.9
0.1~10.0
0.00~599.00
0.00~599.00
xxx0b: R1 A Contact
xxx1b: R1 B Contact
xx0xb: R2 A Contact
(DO2 for F1)
xx1xb: R2 C Contact
0: Hold last set frequency when stopped
1: Set frequency to 0 when stopped
2: Allow speed changes from last set frequen-
cy when stopped
3: Refresh frequency at acceleration.
Range and definition are the same as those of
03-11, 03-12
xxx0b: Photo-coupler A Contact
xxx1b: Photo-coupler B Contact
0: General Pulse Input
1: PWM
Depending on the setting of 03-30
03-30 = 0: 50~32000Hz
03-30 = 1:10~1000Hz
0.0~1000.0
Control mode
Default Unit
V/f
V/f
SLV
+PG
O
O
X
O
O
O
X
X
X
O
O
O
-
-
-
-
-
-
-
-
-
-
-
-
O
O
O
X
X
O
O
O
O
O
O
O
O
O
O
-
-
-
-
-
-
-
-
-
O
O
O
-
-
-
-
-
-
-
-
-
-
-
-
O
O
O
O
O
O
O
O
O
O
O
O
X
X
X
0.0
Hz
O
O
O
2.0
Hz
O
O
O
0.1
A
O
O
O
0.1
s
O
O
O
0.00
Hz
O
O
O
0.00
Hz
O
O
O
0000b
-
O
O
O
0
-
O
O
O
0
-
O
O
O
0000b -
O
O
O
0
-
O
O
O
1000
Hz
O
O
O
100
%
O
O
O
Attribute
PM
PM
SV
SLV2
SV
SLV
X
X
X
O
O
O
O
O
O
O
X
X
O
O
O
O
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
O
O
O
O
O
O
X
X
X
X
X
X
O
O
X
X
O
O
X
X
-
-
-
-
-
-
-
-
-
-
-
-
O
O
O
O
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
X
X
O
X
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
*1
O
O
O
O
*1
63

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents