Code
Parameter Name
Acceleration and Decelera-
05-00
tion Selection of Multi-Spe-
ed
*Frequency Setting of
05-01
Speed-Stage 0
*Frequency Setting of
05-02
Speed-Stage 1
*Frequency Setting of
05-03
Speed-Stage 2
*Frequency Setting of
05-04
Speed-Stage 3
*Frequency Setting of
05-05
Speed-Stage 4
*Frequency Setting of
05-06
Speed-Stage 5
*Frequency Setting of
05-07
Speed-Stage 6
*Frequency Setting of
05-08
Speed-Stage 7
*Frequency Setting of
05-09
Speed-Stage 8
*Frequency Setting of
05-10
Speed-Stage 9
*Frequency Setting of
05-11
Speed-Stage 10
*Frequency Setting of
05-12
Speed-Stage 11
*Frequency Setting of
05-13
Speed-Stage 12
*Frequency Setting of
05-14
Speed-Stage 13
*Frequency Setting of
05-15
Speed-Stage 14
*Frequency Setting of
05-16
Speed-Stage 15
Acceleration Time Setting
05-17
of Multi Speed 0
Deceleration Time Setting
05-18
of Multi Speed 0
Acceleration Time Setting
05-19
of Multi Speed 1
Deceleration Time Setting
05-20
of Multi Speed 1
Acceleration Time Setting
05-21
of Multi Speed 2
Deceleration Time Setting
05-22
of Multi Speed 2
Acceleration Time Setting
05-23
of Multi Speed 3
Deceleration Time Setting
05-24
of Multi Speed 3
Acceleration Time Setting
05-25
of Multi Speed 4
Deceleration Time Setting
05-26
of Multi Speed 4
Acceleration Time Setting
05-27
of Multi Speed 5
Deceleration Time Setting
05-28
of Multi Speed 5
Acceleration Time Setting
05-29
of Multi Speed 6
66
Group 05: Multi-Speed Parameters
Setting Range
0: Acceleration and deceleration time are
set by 00-14 ~ 00-24
1: Acceleration and Deceleration Time are
set by 05-17 ~ 05-48
0.00~599.00
0.00~599.00
0.00~599.00
0.00~599.00
0.00~599.00
0.00~599.00
0.00~599.00
0.00~599.00
0.00~599.00
0.00~599.00
0.00~599.00
0.00~599.00
0.00~599.00
0.00~599.00
0.00~599.00
0.00~599.00
0.1~6000.0
0.1~6000.0
0.1~6000.0
0.1~6000.0
0.1~6000.0
0.1~6000.0
0.1~6000.0
0.1~6000.0
0.1~6000.0
0.1~6000.0
0.1~6000.0
0.1~6000.0
0.1~6000.0
Default
Unit
V/f
V/f
SLV
+PG
0
-
O
O
5.00
Hz
O
O
5.00
Hz
O
O
10.00
Hz
O
O
20.00
Hz
O
O
30.00
Hz
O
O
40.00
Hz
O
O
50.00
Hz
O
O
50.00
Hz
O
O
5.00
Hz
O
O
5.00
Hz
O
O
5.00
Hz
O
O
5.00
Hz
O
O
5.00
Hz
O
O
5.00
Hz
O
O
5.00
Hz
O
O
5.00
Hz
O
O
10.0
s
O
O
10.0
s
O
O
10.0
s
O
O
10.0
s
O
O
10.0
s
O
O
10.0
s
O
O
10.0
s
O
O
10.0
s
O
O
10.0
s
O
O
10.0
s
O
O
10.0
s
O
O
10.0
s
O
O
10.0
s
O
O
Control mode
PM
PM
SV
SLV2
SV
SLV
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O