gefran VDI100 Series Instruction Manual page 87

General purpose full vector inverter
Hide thumbs Also See for VDI100 Series:
Table of Contents

Advertisement

Code
Parameter Name
Mode Selection of Automa-
17-00
tic Tuning*
17-01 Motor Rated Output Power
17-02 Motor Rated Current
17-03 Motor Rated Voltage
17-04 Motor Rated Frequency
17-05 Motor Rated Speed
17-06 Pole Number of Motor
17-07 PG Pulse Number
17-08 Motor no-load Voltage
17-09 Motor Excitation Current
17-10 Automatic Tuning Start
Error History of Automatic
17-11
Tuning
Proportion of Motor Leaka-
17-12
ge Inductance
17-13 Motor Slip Frequency
Selection of Rotation
17-14
Auto-tuning
kVA: The default value of this parameter will be changed by different capacities of inverter.
*: The default value is 1 in VF/ VF+PG mode while the default value is 0 in SLV/ SV/ SLV2 mode.
*: It is suggested that HD/ ND mode (00-27) and application presets (00-32) be selected first before motor performs auto-tuning.
Note: The value of mode selection of automatic tuning is 6 (Static Auto-tuning Combination). When do auto-tuning with no-load motor, it suggest select 17-00=5 (Rotation
Auto-tuning Combination)
** Displayed when 17-00=2
Code
Parameter Name
Slip Compensation Gain at
18-00
Low Speed.
Slip Compensation Gain at
18-01
High Speed.
18-02 Slip Compensation Limit
VDI100 • Instruction manual
Group 17: Automatic Tuning Parameters
Setting Range
0: Rotation Auto-tuning
1: Static Auto-tuning
2: Stator Resistance Measurement
3: Reserved
4: Loop Tuning
5: Rotation Auto-tuning Combination
(item: 4+2+0)
6: Static Auto-tuning Combination (item:
4+2+1)
0.00~600.00
0.1~1200.0
230V: 50.0~240.0
400V: 100.0~480.0
5.0~599.0
0~24000
2~16 (Even)
0~60000
230V: 50~240
400V: 100~480
0.01~600.00
0: Disable
1: Enable
0: No error
1: Motor data error
2: Stator resistance tuning error
3: Leakage induction tuning error
4: Rotor resistance tuning error
5: Mutual induction tuning error
6: Encoder error
7: DT Error
8: Motor's acceleration error
9: Warning
0.1~15.0
0.10~20.00
0: VF Rotation Auto-tuning
1: Vector Rotation Auto-tuning
Group 18: Slip Compensation Parameters
Setting Range
0.00~2.50
-1.00~1.00
0~250
Default
Unit
V/f
V/f
+PG
-
O
O
VF:2
VF+PG:2
SLV:6
SV:6
SLV2:6
kVA
kW
O
O
kVA
A
O
O
220
V
O
O
440
60.0
Hz
O
O
kVA
rpm
O
O
4
Pole
O
O
1024
ppr
O
O
-
V
O
O
-
A
X
X
0
-
O
O
0
-
O
O
3.4
%
X
X
1.78**
Hz
X
X
0
-
O
O
Default
Unit
V/f
V/f
+PG
VF:0.00
-
O
X
SLV*
0.0
-
O
X
200
%
O
X
Control mode
PM
PM
SLV
SV
SLV2
SV
SLV
O
O
X
X
O
O
O
X
X
O
O
O
X
X
O
O
O
X
X
O
O
O
X
X
O
O
O
X
X
O
O
O
X
X
O
O
O
X
X
O
O
O
X
X
O
O
O
X
X
X
O
O
X
X
O
O
O
X
X
O
O
O
X
X
X
O
O
X
X
X
O
O
X
X
O
Control mode
PM
PM
SLV
SV
SLV2
SV
SLV
O
O
X
X
O
O
X
X
X
X
X
X
X
X
X
Attribute
Attribute
*1
*1
87

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents