gefran VDI100 Series Instruction Manual page 110

General purpose full vector inverter
Hide thumbs Also See for VDI100 Series:
Table of Contents

Advertisement

Example 2: After one or more parameters in 00-41 ~ 00-56 are set, user parameters settings are as follows.
Steps
Group
13 Driver Status
1
14 PLC Setting
15 PLC Monitor
PARA
-06. Access Level
2
-07. Password 1
-08. Initialize
Edit
-------------------------
3
1 User Level
(0~2)
< 2 >
-ADV-
Access Level
4
1
(0-2)
< 2 >
PARA
5
-06. Access Level
Group
6
00.User Function
Monitor
12-16=000.00Hz
7
------------------------
12-17=000.00Hz
12-18=0000.0A
Group
8
00. User Function
13.Driver Status
PARA
9
-41.
Edit
10
00
(00~57)
< 00 >
Edit
11
06
(00~57)
< 00 >
Edit
12
----------------------------------
12-17=000.00Hz
12-18=0000.0A
110
LCD Display
Select the start parameter group (03) in the advanced modes.
13
Press (READ/ ENTER) and ▲ (Up) / ▼ (Down) key to enter the access level of parameter
(13-06).
13-06
Access Level
Press (READ/ ENTER) key to enter the screen of the data setting/ read.
* The selected setting value will flash.
Press ▲(Up) / ▼ (Down) key to change setting value to 1 (13-06=1, user level) and Press
(READ/ ENTER) key to save the setting value (03-00). Then, the digit stops flashing and the
G01-02
screen displays the setting value. Few seconds later, the selected digit will flash again.
User Level
User level (13-06=1) can be set by one or more parameters in the user parameters of 00-41
~ 00-56. If users do not set user parameters, 13-06 will not be set in the user level (setting
value=1).
13
Press (DSP/FUN) key to the display of subdirectory.
Press (DSP/FUN) key to the display of group directory. It is required to press ▲ (Up) key to
select Group 00 User Function.
Freq Ref
Press (DSP/ FUN) key to enter the main screen. If user would like to leave the screen of user
parameters, press RESET key and then DSP/FUN key to select parameter Group 13. Hotkeys
are only enabled in inverter software V1.4.
13-06 can be selected to be adjusted so leave parameters or enter parameter group 00 to edit
user parameters is allowable.
00
Press (READ/ ENTER) key and ▲(Up) / ▼ (Down) key to select user parameter 0 (00-41)
S1 Function Sel
display.
Press (READ/ ENTER) key to enter the screen of data setting/ read.
00-41
*The selected setting value will flash.
S1 Function Sel
2-Wire (FWD-RUN)
In this example, 03-00 (Multi-function terminal Function Setting-S1)
has been defined as user parameters (00-41). The right bottom
< 03-00 >
location displays the original parameter group.
Press ▲ (Up) / ▼ (Down) key to change the setting value to 2. Use (READ/ ENTER) key to
00-41
save the setting value.
S1 Function Sel
FJOG
When the selected setting value does not flash again, the setting
< 03-00 >
value will be saved to 00-41 and 03-00 simultaneousl
00-00
Press (DSP/FUN) key to the display of main screen.
Freq Ref
12-16=000.00Hz
* If users do not press (DSP/ FUN) key in one minute, the screen will automatically display the
monitor mode shown as the left figure. The automatically return time can be set via 16-06.
Descriptions
VDI100 • Instruction manual

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents