gefran VDI100 Series Instruction Manual page 325

General purpose full vector inverter
Hide thumbs Also See for VDI100 Series:
Table of Contents

Advertisement

15: ASR output
16: Reserved
17: q-axis voltage
18: d-axis voltage
19: Reserved
20: Reserved
21: PID input
22: PID output
23: PID target value
24: PID feedback value
25: Output frequency of the soft starter
26: PG feedback
27: Reserved
28: Communication control
Code
Parameter Name / Range
04-12
AO1 gain
0.0~1000.0%
04-13
AO1 bias
-100.0~100.0%
04-16
AO2 function Setting
See parameter 04-11
04-17
AO2 gain
0.0~1000.0%
04-18
AO2 bias
-100.0~100.0%
04-19
AO2 Output Signal Type
0: AO2 0~10V
1: AO2 4~20mA
04-20
Filter Time of AO Signal Scan
0.00~0.50s
VDI100 • Instruction manual
Analog output level adjustment
Analog Output Signal
10V × Gain
10V
{
Bias
0V
{
Bias
0%
-10V
(-10V) × Gain
Monitor Signal
100%
325