9.6.2 The total number of horizontal dots
Top → INPUT TIMING → H TOTAL DOTS
Menu
Setting for
Each input channel, each input signal (only analog input signal)
Setting value 400DOT to 4125DOT [Default] varies depending on the input signal.
You can set the total number of horizontal dots of analog RGB/analog YPbPr input video.
The settable values vary depending on the input signal. If interlace signal are input, the sampling clock
(Holizontal shyncronized frequency x the total number of holizontal dots) must be within 13 MHz to 81 MHz.
If non-interlace signal are input, the sampling clock must be within 13 MHz to 162 MHz.
If other signal is input, the total number only can be displayed but not set.
If there is no input signal on the input channel it shows "NOT AVAILABLE NOW" on the front VFD screen.
9.6.3 Start position
Top → INPUT TIMING → H START (Horizontal) / V START (Vertical)
Menu
Setting for
Each input channel, each input signal
Setting value [Table 9.5] Setings of start position
Function
Horizontal start position
Vertical start position
[Default] varies depending on the input signal.
You can set the horizontal/vertical starting position.
Setting value must be as follows. If the set value exceeds the value, the starting position will be set the limit
value within the settable range automatically.
Horizontal : The total number of horizontal dots > Horizontal active area > Horizontal starting position
Vertical
: The total number of vertical lines > Vertical active area > Vertical starting position
If there is no input signal on the input channel it shows "NOT AVAILABLE NOW" on the front VFD screen.
[Table 9.5] Setings of start position
64DOT to 2900DOT
(The total number of horizontal dots-Horizontal active area or less)
10LINE to 2048LINE
(The total number of vertical lines-Vertical active area or less)