Precautions; Installation - IDK MSD-72 Series User Manual

4k@60 and hdcp 2.2 supported digital multi switcher
Hide thumbs Also See for MSD-72 Series:
Table of Contents

Advertisement

MSD-72 Series User's Guide

7 Precautions

Before connecting to external devices, follow the precautions below.

7.1 Installation

When installing the MSD, please observe the following precautions.
● Do not place the MSD on top of another MSD.
● Do not block vent holes. Please secure the space above ambient 30 mm/1.18 inches.
● Do not install the MSD to an enclosed space. When the MSD needs to be installed to EIA rack mount
or an enclosed space, please prepare ventilating equipment to keep the ambient temperature at 40
degrees C/104 degrees F or less. If inadequately vented, the life of parts may be shortened and
operations may be affected.
■ Attaching rack mounting brackets
1.
Remove four M5 screws from one side of the unit. Retain these screws for step 2.
2.
Attach one bracket to the side of the unit using the screws removed in step 1.
3.
Repeat steps 1 and 2 on the other side of the unit.
Rack size
EIA rack 2U
Installation
Model
MSD-7201UHD, MSD-7201UHDTB
number
MSD-7202UHD, MSD-7202UHDTB
Note:
The standard screw tightening torque is 2.94 N・m (about 30 kgf・cm).
22
[Table 7.1] Attaching rack mounting brackets
EIA rack 3U
MSD-7203UHD, MSD-7203UHDTB
MSD-7204UHD, MSD-7204UHDTB

Advertisement

Table of Contents
loading

Table of Contents