1. Compressor mounting bolt
2. Magnet clutch assembly
1. Compressor
mounting bolt
7) Loosen compressor mounting bolt, then remove compressor
from its mounting bracket.
8) Drain compressor oil from compressor, and measure its
amount.
NOTE:
When removing compressor, be careful not to damage fins
of condenser.
INSTALLATION
Reverse removal procedure noting the following point.
D Tighten compressor mounting bolt as below order.
Compressor mounting bolt tightening order: (a) " (b) " (c)
D Tighten compressor mounting bolt as specified torque.
Tightening Torque
(a), (b) and (c): 26 N·m (2.6 kg-m, 19.0 lb-ft)
D Pour new compressor oil with the same amount as that drained
from compressor.
D Evacuate and charge system according to previously described
procedure.
NOTE:
Compressor supplied from factory is filled up with speci-
fied amount of compressor oil.
Compressor oil amount: 120 cm
AIR CONDITIONING (OPTIONAL) 1B-9
3
(120 cc)