Diagnosing Electrical Malfunctions
Page 8-9
Trouble with the charging system may be indicated by the U ^ M
ammeter.
\ — /
Abnormal Ammeter Operation
Check the ammeter for normal operation as shown below.
Engine
Switch
Ammeter
Stopped
Off
o
Stopped
On
Running
On
+
Switch On, Negative (-) on Ammeter, Engine
6£\
Running.
If the ammeter is indicating a discharge during engine
operation, inspect the alternator drive pulley and drive belt for
slippage.
Abnormal Charging System Operation
Check the battery and all wiring connections.