Cooling System
DODGE Turbo Diesei
Cooiing System Replacement Procedures
Page 7-11
Fan Pulley - Replacement
36mm
Remove the fan.
The thermatic fan housing is threaded onto the fan hub shaft,
with left hand threads. Turn the 36mm nut clockwise (as viewed
from the front) to loosen.
3/8 inch Drive B a r , 10mm
Remove the fan belt.
Remove the six capscrews and replace the fan pulley.
Torque Value: 9 N-m [7 ft-lbs]
Coolant - Draining
Warning: Walt until the temperature is below 50°C
[120°F] before removing the coolant system pressure
cap. Failure to do so can cause personal injury from
heated coolant spray.
Drain the coolant system by opening the drain valve on the
radiator. A drain with a capacity of 20 liters [5 U.S. gallons] will
be adequate to hold the coolant.