Ready Delay Time; Service Interval Time - Nordson ProBlue P4 Customer Product Manual

Adhesive melters
Table of Contents

Advertisement

3
4
5
E 2014 Nordson Corporation
Change History Log
Description:
Records the last ten changes made to either the set-point temperatures
or the operating parameters.
Value:
Resolution:
Default Value:
P-_ (unused log entry)
Format:
Refer to Section 3, Installation. Review Parameter and Set-point
Temperature Changes.
Use:
Use the right-display key to review the log entries for the last ten
changes that were made to the operating parameters or the set-point
temperatures. Empty log entries are indicated by "P-_."

Ready Delay Time

Description:
The amount of time that will elapse after all of the components have
reached their set-point temperature before the ready LED will turn on.
The ready delay time only functions when the temperature of the tank,
at the time the melter is turned on, is more than 27 C (50 F) from its
set-point temperature. The ready delay time begins when all
components are within 3 C (5 F) of their respective set-point
temperature.
Value:
0 to 60 minutes
Resolution:
1 minute
Default Value:
0 minutes
Format:
Left display "rd". Right display, minutes or seconds remaining
Use:
The ready delay allows the contents of the tank an additional amount of
time to heat before pump turns on.
NOTE: The time remaining on the ready delay is indicated in minutes in
the right display at the end of every automatic scan cycle. The left
display indicates "rd" whenever the time remaining appears. When the
delay time reaches 1 minute, the time remaining appears in seconds.

Service Interval Time

Description:
The number of heater-on hours that must elapse before the service LED
turns on.
Value:
0 hours (disabled) to 8736 (one year)
Resolution:
1 hour
Default Value:
500 hours
Format:
Use:
Set the service interval time to signal a user-defined service check or
maintenance event, such as changing the filter. The service LED will
turn on after the pre-set time elapses. With the melter in the scan mode,
press the Clear/Reset key to turn off the service LED and reset the
time.