Remove The O‐Ring And The Pump Seal - Nordson ProBlue P4 Customer Product Manual

Adhesive melters
Table of Contents

Advertisement

D-30
SP Pump Diagnostics and Repair
Remove the O‐ring and the Pump Seal
Part 1024496_06
See Figure D‐16.
Remove the O‐ring (1) and pump seal (2) from the pump body.
O‐ring
P/N 940172
Pump Seal
P/N 273139
Special Reassembly Instructions
S
The O‐ring and the pump seal are replaced after the piston is reinstalled,
but before the insulator and pump frame are installed. Refer to Removing
the Pump Frame and the Insulator for information about reinstalling the
O‐ring and the pump seal.
1
2
Figure D-16
1. O‐ring
2. Pump Seal
Check/Repair
Nicked, cut, deteriorated,
or swollen
Nicked, cut, deteriorated,
or deformed
Apply Parker lubricant
during reassembly
Apply Parker lubricant
during reassembly
E 2014 Nordson Corporation

Advertisement

Table of Contents
loading

This manual is also suitable for:

Problue p10Problue p7

Table of Contents