To adjust the set‐point temperature of an individual component
(contd)
If you enter a valid set‐point temperature
for a hose/gun that is not connected to
the melter or if you enter a set‐point
temperature that is out of range, the right
display will indicate dashes (‐‐‐‐) for three
seconds and then change back to the
original set‐point temperature.
When the right display is flashing, you can
quickly change the current set‐point
temperature to 0 degrees (off) by
simultaneously pressing both of
right‐display scroll keys.
After removing a hose or a gun, use
the individual component method of
set‐point temperature adjustment to set
the component's temperature to zero
degrees (off). This will avoid causing an
F1 fault when a hose or gun is added.
The factory set‐point temperature of the
tank is
175 _C (350 _F). The factory
set‐point temperature of all others
components is zero degrees (off).
When the units of temperature is set
to degrees Celsius, the minimum and
maximum set‐point temperatures are 40
_C and 230 _C. When the units of
temperature are set to degrees
Fahrenheit, the minimum and maximum
set‐point temperatures are 100 _F and
450 _F.