B-12
Operating Parameters

Output Setup

40 - 42
43 - 46
Part 1024496_06

Standard Outputs 1, 2, and 3

Description:
Determines the function of the output.
Value:
0 = Output Disabled
1 = Ready
2 = Ready and Pump is on
3 = Fault
4 = Low level
5 = Service LED is on
6 = Alert (Potential fault)
Resolution:
1
Default Value:
Output 1 = 1
Output 2 = 3
Output 3 = 4
Format:
Use:
Refer to Installing Melter Outputs in Section 3, Installation, for
information on setting up outputs.
When control option 6, Alert is selected, the output is active whenever
the melter enters the two minute fault monitoring period. If the potential
fault condition clears before the end of the two minute period, the output
signal ends. Refer to Section 4, Operation, Monitor Melter Faults, for
information about fault monitoring.

Optional Outputs 4, 5, 6, and 7

Description:
Control options that determine the function of the four optional outputs
provided when the optional I/O expansion card is installed on the CPU
board.
Value:
0 = Output Disabled
1 = Ready
2 = Ready and Pump is on
3 = Fault
4 = Low level
5 = Service LED is on
6 = Alert (Potential fault)
Resolution:
1
Default Value:
0 (all optional outputs)
Format:
Use:
Refer to the instruction sheet provided with the optional I/O expansion
card for information about wiring and setting up the optional outputs.
When control option 6, Alert is selected, the output is active whenever
the melter enters the two minute fault monitoring period. If the potential
fault condition clears before the end of the two minute period, the output
signal ends. Refer to Section 4, Operation, Monitor Melter Faults, for
information about fault monitoring.