Nordson ProBlue P4 Customer Product Manual page 44

Adhesive melters
Table of Contents

Advertisement

3-14
Installation
Configuring the Electrical Service
Opening the electrical enclosure
door
Electrical connector
(P/N 1022993)
Part 1024496_06
WARNING! Risk of electrocution! Install a lockable power disconnect switch
between the electrical service and the melter. Failure to install or properly
use the disconnect switch when servicing the melter can result in personal
injury, including death.
2. Open the electrical enclosure door.
3. Route the power cable into the wire tray in the base of the electrical
enclosure.
NOTE: If the power cable cannot be routed through the conduit knockout
provided in the sub‐base (Refer to Mounting the Melter earlier in this
section), route the cable through the optional knockout provided on the
left side of the chassis.
See Figure 3‐5.
4. Connect each power cable lead to the appropriate terminal on the
electrical connector (P/N 1022993). Table 3‐3 describes the terminal
connections for each type of electrical service.
5. Plug the electrical connector into receptacle TB1 on the main board.
6. Connect the ground lead from the power cable to the ground lug that is
located on the chassis. The lug is marked PE/G.
7. Connect the ground jumper that is connected to the ground lug, to the
ground post that is located on the sub‐base.
(contd)