Nordson ProBlue P4 Customer Product Manual page 58

Adhesive melters
Table of Contents

Advertisement

3-28
Installation
Operating Parameters
Parameter
Standard
0
Enter Password
1
Total Hours with Heaters On
(noneditable)
2
Fault Log (noneditable)
3
Change History Log (noneditable)
4
Ready Delay Time
5
Service Interval Time
6
Service LED Heater Hours
8
Automatic Pump On
9
Automatic Pump On Temperature
10
Enable or Disable Password
11
Create Password
14
External Communications Lock‐out
Temperature Control
20
Temperature Units (degrees _C or _F)
21
Over Temperature Delta
22
Under Temperature Delta
23
Standby Delta
24
Automatic Standby Timeout
25
Automatic Heaters Off Time
26
Manual Standby Time
Input Setup
30
Standard Input 1
31
Standard Input 2
32
Standard Input 3
33
Standard Input 4
34
Optional Input 5
35
Optional Input 6
36
Optional Input 7
37
Optional Input 8
38
Optional Input 9
39
Optional Input 10
Part 1024496_06
(contd)
Table 3‐6 Operating Parameters
Name
0 to 9999
0-999,999
0 to 60 minutes
0 to 8736 hours
0 to 9999 hours
0 (disabled) or 1 (enabled)
0 (disabled) or (1 to 230 C)
0 (disabled) or 1 (enabled)
0 to 9999
0 or 1
C (degrees Celsius) or F
(degrees Fahrenheit)
5 _C (10 _F) to 60 _C (110 _F)
5 _C (10 _F) to 60 _C (110 _F)
25 _C (50 _F) to 190 _C (350 _F)
0 to 1440 minutes
0 to 1440 minutes
0 to 180 minutes
0-10, 15-16
0-9, 15-16
0-9, 15-16
0-9, 15-16
0-9, 15-16
0-9, 15-16
0-9, 15-16
0-9, 15-16
0-9, 15-16
0-9, 15-16
Range of Values
Default Value
4000
0
_‐F0 (empty)
P‐_ (empty)
0 minutes
500 hours
0
1 (enabled)
0 (disabled)
0 (disabled)
5000
0 (disabled)
C (degrees Celsius)
15 _C (25 _F)
25 _C (50 _F)
50 _C (100 _F)
0 (disabled)
0 (disabled)
0 (disabled)
10 (Automatic
Standby)
1 (Standby on/off)
2 (Heaters on/off)
4 (Hose/gun 1
enable/disable)
0 (disabled)
0 (disabled)
0 (disabled)
0 (disabled)
0 (disabled)
0 (disabled)
Continued...