Nordson ProBlue P4 Customer Product Manual page 161

Adhesive melters
Table of Contents

Advertisement

Problem
Is the air supply to the melter
turned off or is the plant air
pressure low?
+
Turn on or adjust the plant air
pressure.
Is the operating air pressure set
correctly?
Refer to Section 4.
+
Is air being supplied to the top of
the pump?
+
Continued
on next
page....
Is 24 VDC being supplied to the
solenoid valve (wire harness
leads 9 and 10)?
+
Replace the pneumatic
assembly.
P/N 1028307.
T.4.2
Starting conditions:
No faults >
Ready LED is illuminated >
Adjust the operating air
No hot melt output from all guns >
pressure for the current
Pump has stopped >
manufacturing process.
Pump LED is illuminated >
Tank set-point temperature is OK >
Pump is not controlled by a remote input
Are the yellow and green air lines
to the pneumatic assembly
connected properly?
See Figure 6-4.
+
Do the wires at Pins 9 and 10 on
the J7 wire harness lack
continuity?
Connect securely. See Figure
6-2.
+
Replace the J7 wire harness.
P/N 1024600.
Connect securely.
Replace the main board.
P4/P7 − P/N 1028322.
P10 − P/N 028323.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Problue p10Problue p7

Table of Contents