Schedule 3 Exit Standby; Schedules For Monday - Nordson ProBlue P4 Customer Product Manual

Adhesive melters
Table of Contents

Advertisement

B-20
Operating Parameters
Seven‐day Clock
68
71
Part 1024496_06
(contd)

Schedule 3 Exit Standby

Description:
Used to set the time that the melter will exit the standby mode during
schedule 3.
Value:
0000 to 2359, - - - -
Resolution:
1 minute
Default Value:
- - - -
Format:
Hour, Hour: Minute, Minute
Use:
Set the time that the melter will exit the standby mode during schedule
3.
To disable this parameter, set the parameter's value to "- - - -" by
simultaneously pressing both of the right-display scroll keys.
Note: Do not set an exit standby time that is outside of the time period
defined by the schedule's heater on and off time. The melter cannot
enter the standby mode when the heaters are off.

Schedules for Monday

Description:
Used to select which schedule(s) should be used on Monday.
Value:
0 – Remain at last clock transition
1 – Use just schedule 1
2 – Use just schedule 2
3 – Use just schedule 3
4 – Use schedule 1 and 2
5 – Use schedule 2 and 3
6 – Use schedule 1 and 3
7 – Use schedule 1, 2, and 3
Resolution:
1
Default Value:
0
Format:
Use:
Selects the active schedule(s) for the day.
NOTES: If the 0 schedule option is used, the heaters will not turn on
again until the next scheduled heaters on time arrives.
E 2014 Nordson Corporation

Advertisement

Table of Contents
loading

This manual is also suitable for:

Problue p10Problue p7

Table of Contents

Save PDF