E-6
400/480 Volt ProBlue Adhesive Melters
Installation
Clearances
Figure E‐1
Minimum installation clearances (P4 top and front views shown)
Item
The distance from the outside edge of a
to the front face of the melter when a short 90‐degree hose
A
fitting is to connect the hose to the melter
The clearance required to open the pump enclosure door
B
The distance from the melter sub‐base to the front edge of the
tank lid when the lid is at its highest point.
C
The clearance required on the left side of the melter to open the
electrical enclosure door or remove a hose/gun module.
D
Part 1024496_06
Before installing the transformer, familiarize yourself with the Section 3,
Installation.
NOTE: ProBlue 400/480 volt transformers can only be used in conjunction
with ProBlue adhesive melters that are specifically designed for use with
440/480 volt electrical service.
Figure E‐1 illustrates the minimum clearances that are required between the
melter and surrounding objects. Table E‐2 describes each clearance.
A
B
Table E‐2 Installation Clearances
Description
5
/
‐inch Nordson hose
16
D
Required Clearance
P4 = 370 mm (14.5 in.)
P7 = 370 mm (14.5 in.)
P10 = 391 mm (15.4 in.)
P4 = 243 mm (9.6 in.)
P7 = 243 mm (9.6 in.)
P10 = 268 mm (10.55 in.)
P4 = 575 mm (22.6 in.)
P7 = 637 mm (25.1 in.)
P10 = 729 mm (28.7 in.)
P4 = 689 mm (27.1 in.)
P7 = 752 mm (29.6 in.)
P10 = 755 mm (29.7 in.)