Installation
If the Electrical Service Type is..
400/230 VAC 3‐phase
(4‐wire service, including a
neutral) See note.
230 VAC 1‐phase
(2‐wire service, including a
neutral) See note.
200 to 240 VAC 3‐phase
(3‐wire service without a
neutral)
200 to 240 VAC 1‐phase
(2‐wire service without a
neutral)
NOTE: The 400/230 VAC 3‐phase service (4‐wire service including neutral) includes the 415/240 VAC
3‐phase (4‐wire service, including neutral) voltage. The 230 VAC 1‐phase service (2‐wire service,
including a neutral) includes the 240 VAC 1‐phase (2‐wire service, including a neutral) voltage.
Voltage plugs with and without the
neutral lead
Part 1024496_06
To connect a power cable to the melter
Table 3‐3 Electrical Service Information
Use Electrical Connector
L1
   
3/N/PE AC
400/230V
1/N/PE AC
200–240V
  
3/PE AC
200–240V
 
1/PE AC
200–240V

To connect a voltage plug to the melter

1. Refer to Table 3‐3 to determine the part number of the voltage plug that
matches the required electrical service.
NOTE: Each voltage plug is color‐coded and is labeled with its part
number and service type.
See Figure 3‐6.
2. Insert the correct voltage plug into receptacle J1 on the main board.
Ensure that the plug snaps into place. If the plug contains a neutral lead,
connect the neutral lead to receptacle J2 on the main board.
3. When the electrical service is completely installed and inspected in
accordance with local electrical codes and standards, close the electrical
enclosure door and switch the local power disconnect switch on.
If the electrical service was configured correctly, the melter control panel
will display dashes.
(contd)
Terminals..
L2
L3
N
Use Voltage Plug..
227569
Red/Yellow
232617
Blue/Yellow
227568
Red/Green
227567
Blue/Green