Electrical Specifications; Pump Specifications; Melter Power Requirements - Nordson ProBlue P4 Customer Product Manual

Adhesive melters
Table of Contents

Advertisement

8-2
Technical Data

Electrical Specifications

Item
Hose/gun heating capacity
Control temperature range
Control temperature accuracy
International Protection (IP) rating
Input voltage tolerance
NOTE
A:
Dependent on melter configuration and addition of optional hose/gun modules
B:
Flow set-point at RTD

Pump Specifications

Air pressure while running
Minimum air pressure
Viscosity range
Maximum hydraulic pressure
Air consumption at 415 kPa (60 psi) and maximum pump
speed
Displacement
Maximum speed

Melter Power Requirements

Melter
P4
P7
P10
Part 1024496_06
Item
Number of
1‐Phase Power
Hose/Guns
Draw (Amps)
2
4
2
4
2
4
6
Data
2, 4, or 6 hose/gun pairs
40 to 230 C (100 to 450 F)
1 C
IP54
+10%, -15%
70 to 689 kPa (10 to 100 psi)
0.7 bar (10 psi)
800 to 10,000 cps
15:1 pump: 10.3 MPa (1500 psi)
6:1 pump: 4.14 MPa (600 psi)
46 l/min. (1.6 scfm)
7.20 ml/stroke ( 0.44 in
90 strokes/min.
Without Neutral
17
26
18
27
18
27
35
Data
3
/stroke)
3‐Phase Power (Amps)
With Neutral
15
9
23
17
16
10
24
17
16
10
24
17
31
18
E 2014 Nordson Corporation
Note
A
B

Advertisement

Table of Contents
loading

This manual is also suitable for:

Problue p10Problue p7

Table of Contents

Save PDF