When using the right‐display scroll keys to
adjust a set‐point temperature, the right
display
automatically increments between 0, 175,
and 230 _C or between 0, 350, and 450
_F.
If you make a mistake while you are
changing a set‐point temperature, but you
have not yet pressed the enter key, press
the Clear/Reset key to reset the right
display to the original temperature.
The melter will exit the setup mode
and return to the automatic scan mode
two minutes after the last key is pressed.
A global set‐point temperature of zero
degrees (Celsius or Fahrenheit) turns all
components off.
When scrolling through component
numbers in the left display, component
numbers that are associated with unused
hose/gun receptacles are skipped.
The melter stores a record of the last
ten changes made to the set‐point
temperatures (and operating parameters)
in the change history log.
You can save set‐point temperature
changes by simultaneously pressing the 1
key and the Setup key.