Intended Use; Limitations Of Use; Modes Of Operation - Nordson ProBlue P4 Customer Product Manual

Adhesive melters
Table of Contents

Advertisement

2-4
Description

Intended Use

Limitations of Use

Modes of Operation

Part 1024496_06
ProBlue melters are specifically designed to:
S
Melt and pump solid‐form hot melt materials that are engineered to be
liquified and extruded at temperatures below 230 _C (450 _F)
S
Be used with compatible hot melt hoses and guns that are
manufactured by Nordson Corporation
S
Be used in non‐explosive environments
Use ProBlue melters only for the purpose for which they are designed.
ProBlue melters should not be used
S
to melt or pump polyurethane reactive or polyamid hot melt materials
or any other material that creates a health or safety hazard when
heated
S
in environments that will require the melter to be cleaned using a
water wash or spray
ProBlue melters operate in the following modes:
Automatic scan—The melter automatically checks and displays the
current temperature of the tank, hoses, and guns to confirm that they are
within their pre‐defined temperature range. By default, the melter is
always in the automatic scan mode unless it is placed into another
operating mode.
Standby—The temperatures of the tank, hoses, and guns are reduced
down from their operating temperature (hereafter referred to as set‐point
temperature) by a pre‐set number of degrees.
Setup—The setup mode is used to configure melter control options and
features and to review stored operating data. To prevent unauthorized
changes to the melter's configuration, the melter can be
password‐protected
Fault—The melter alerts the operator when an abnormal event occurs.
E 2014 Nordson Corporation